What aluminium strip is

Aluminium strip is thin flat stock in the form of a long band supplied in coils. The requirements for it are set out in GOST 13726. Unlike sheet, it is uncoiled and fed into machines continuously, so strip is used in production where parts are stamped, profiled or bent in series. It is light, plastic, conducts heat and current well and is corrosion resistant.

Alloys and tempers

AlloyPurpose
AD0, AD1 (1050)Soft, plastic, for stamping and bending
AMts (3003 H24)Stronger than pure aluminium, corrosion resistant
AD31NIncreased stiffness, for profiled parts
D16High strength, for parts under load

Soft or half-hard

Soft strip in the M temper bends and stamps easily, but a part made of it is less stiff. Half-hard strip in the H24 temper holds its shape better and suits profiling and products that must keep their size. What temper exactly is needed depends on how the strip is processed: soft is taken for complex bends, and work-hardened for rigid bars and screens.

Sizes and slitting

The thickness of the strip in the catalog varies from 0.28 to 1 mm and the width is 500, 1000, 1200 or 1250 mm. An example item: 0.28 by 1250 mm of the alloy 3003 H24. A coil can be slit into narrower bands of the needed width, so strip is ordered for a specific part. The edge after slitting is checked for burrs, and coils are stored in a dry place and transported in a horizontal position so that the edges do not get crushed.

Where it is used

Strip goes into ventilation and ducts, thermal insulation casings, heat exchangers, radiators and cooling fins. In electrical engineering it is used to make busbars, windings and cable screens. It is also used in packaging, food containers, cladding and decorative profiles. In these products aluminium is valued for its low weight, plasticity and ability not to corrode for a long time.

Strip in electrical engineering

Aluminium conducts current noticeably worse than copper, but is much lighter and more accessible, so for the same conductivity its cross-section is taken larger. Strip goes into busbars, flexible connections and cable screens. The contact surfaces are cleaned of the oxide film before joining, and the junctions with copper are made through special transition elements so that the contact does not deteriorate with time.

Storing coils

Coils of strip are stored in a dry room, in a vertical or horizontal position on supports that do not crush the edge. Damp storage of a tightly wound coil leaves spots between the turns, so it is not left in a cold place with temperature swings where condensation forms. An opened coil is secured so that it does not unwind and damage the edges.

Common mistakes

  • choosing a hard temper for deep stamping;
  • not ordering slitting to the needed width and losing metal to waste;
  • joining the strip to copper without a transition element.

How to choose and what to state

  • the thickness and width of the strip;
  • the alloy and temper, soft or half-hard;
  • whether the coil must be slit into narrower bands;
  • how the strip is processed, to pick the temper.

Related sections

Need a consultation?

Leave a request — we'll call you and help with selection and calculation.