What an I-beam is

An I-beam, or steel beam, has a section in the shape of the letter “H” or “I”: two flanges joined by a vertical web. This shape gives maximum bending rigidity with minimum metal weight, so the I-beam is the main element of load-bearing structures: floors, purlins, columns and crane runways. It works best when the load acts in the plane of the web.

Standards

The range of domestic I-beams is set by GOST 8239 for ordinary beams and GOST 26020 for beams with parallel flange faces. The catalog also contains I-beams to GOST 57837 and GOST 19281, which describes high-strength rolled steel, and the European profiles HEA, HEB and IPE are made to DIN 1025. The standard affects the flange dimensions and tolerances, so when replacing elements it must be kept.

Series B, Sh and K

Under GOST 26020 I-beams are divided into series. The letter B means normal beams, Sh wide-flange and K column beams. The digit after the letter shows the number of the series inside the group, for example B1 and B2. The catalog has the series B1, B2, Sh1, Sh2, K1 and K2. Column and wide-flange beams have wider flanges and work better in compression, so they are chosen for columns.

How to read the designation

In the domestic range the beam number corresponds to its height in centimetres: beam 20B1 has a height of about 200 mm. In European profiles the number shows the nominal height in millimetres: HEA 200 is a profile of the HEA series about 200 mm high. The letters HEA, HEB and HEM mean the light, medium and reinforced series, and IPE a beam with a narrower flange.

Steel grades

Beams are made of steels St3 and 09G2S and of the European S235, S275 and S355. St3 and S235 steel suit ordinary structures, and 09G2S and S355 critical and heavily loaded ones, including at low temperatures. In the catalog the length of beams is most often 12 metres and the height from 10 to 1000 mm.

Where it is used

  • floors, purlins and beams of building frames;
  • bridges, overpasses and crane runways;
  • columns of production shops and warehouses;
  • frames, platforms and equipment frames.

Installation and joints

Beams are joined by welding or bolts through bearing stiffeners and plates. For welded joints the steel is chosen for weldability, and the welded places are protected from corrosion. The bearing areas are checked for crushing, and long beams are supported in the middle so that they do not sag under their own weight during installation.

I-beam or channel

An I-beam is symmetrical and works best in bending in the plane of the web, while a channel is convenient where a flat surface has to be fixed on one side, for example in frames and stairs. For columns and supports that carry load along the axis, I-beams of the column series are taken.

Corrosion and painting

A black beam intended for use outdoors and in damp workshops is protected with primer and paint or galvanized. Before painting the surface is cleaned of scale and rust, and the joints where water collects are made with drainage.

How to choose the beam number

The beam number is chosen by the designer from the load and the span: the greater the span and load, the taller the beam. A profile should not be replaced “by eye” with a smaller one, because rigidity depends on the height cubed. If there is no design yet, contact an engineer, and we will help find the needed profile in the available range.