What a copper busbar is
A copper busbar is a product of rectangular section used as a current-carrying conductor. Busbars made of copper carry large currents with little heating and are corrosion resistant. The requirements for busbars and wire for electrical engineering are set by GOST 434. The length of busbars in the catalog is 3000 mm.
Size of a busbar
The size of a busbar is written as the thickness and width, for example 4 by 20 mm. In the catalog the thickness is 3, 3.5, 4, 5, 6, 8, 10 or 12 mm and the width varies from 20 to 120 mm. Busbars are made of copper M1 and M2. The larger the section, the more current it carries with the same heating, but the permissible load is determined by calculation and not only by the size.
Electrical conductivity and heating
Copper has one of the highest electrical conductivities among technical metals, so it carries large currents with little heating. The permissible current depends on the section area, the cooling conditions and the ambient temperature and not only on the size. The specific section is chosen by the electrician according to the project norms, and the catalog only helps to find metal of the needed dimensions. Impurities reduce conductivity, so copper of high purity is chosen for electrical engineering.
Copper or aluminium
| Parameter | Copper busbar | Aluminium busbar |
|---|---|---|
| Electrical conductivity | Higher, smaller section | Lower, larger section |
| Mass | Heavier | Much lighter |
| Contact stability | High, the oxide conducts | The oxide film needs cleaning |
Cutting, bending and drilling
A busbar is cut with a hacksaw, a saw or a guillotine and the edges are cleaned of burrs. It can be bent edgewise and flatwise with a radius that depends on the thickness: too small a radius cracks hard copper. Hard copper is annealed before bending. Holes for bolts are drilled or punched, but they are made so that enough metal is left near the edge, and burrs are removed so that the contact is flat.
Contact joints
The joint heats up most, so it is made especially carefully. The contact surfaces are cleaned to a shine, sometimes tinned to prevent oxidation, and are tightened with bolts with disc spring washers that maintain the tightening force. An under-tightened or oxidised joint raises resistance and overheats. The junction of copper with aluminium is made through special transition elements, otherwise it is destroyed in a damp environment.
Where it is used
- distribution cabinets, panels and substations;
- grounding and potential equalization;
- power connections and equipment of large currents;
- electric furnaces, welding machines and busways;
- electrical machines and transformers.
Receiving and storage
On receiving, the marking is checked against the copper grade, standard and batch, and the dimensions, the condition of the surface and the absence of deep scratches, dents and stains are checked. Copper is stored in a dry room away from moisture, ammonia vapours, sulphur and acids, because darkening and green deposits appear on the surface. Sheets, busbars and strip are interleaved with paper, and the clean surface is not touched with bare hands, especially where contact is needed.
Common mistakes
- choosing the section only by example without checking the current calculation;
- joining copper to aluminium without a transition piece;
- leaving an oxidised contact without cleaning.
How to choose and what to state
- the thickness and width of the busbar by the current calculation;
- the grade: M1 or M2;
- the condition: hard or soft if the busbar will be bent;
- the length or the size of blanks.